Ventilation calculator (EN 721)
Fixed ventilation is not the same thing as a fan you switch on. EN 721 asks for permanent openings — high to let warm, moist air and combustion products out, low to let replacement air in — sized by habitation floor area.
Pick your van and the numbers below fill themselves from our database of 105 variants.
Optional — leave blank to just get the requirement.
Required high-level free area
10 000 mm²
Required low-level free area
1 500 mm²
Wall high vents must sit at least 1800 mm above the floor and 300 mm above the highest mattress. Low vents go within 100 mm of the floor.
Free area means unobstructed: curtains, cushions and stored gear must never cover a vent.
Planning figures, not certification. Standards are summarised for builders; your inspector, your van's plate and your own measurements always win.
How this is calculated
- EN 721:2019 Table 1 sets both areas from the habitation plan area — 7,500 mm² high and 1,000 mm² low at 5 m², rising to 20,000 / 5,000 mm² above 20 m².
- A high-level opening that is not a roof vent only counts half, so the required area doubles.
- Without any open-flame appliance the requirement drops: 7,500 / 1,000 mm² above 10 m², and 1,500 / 500 mm² below it.
Sources
- EN 721:2019 — Leisure accommodation vehicles: safety ventilation requirements
- EN 1646-1 — Motor caravans: habitation requirements
- Qualigaz / DREAL VASP inspection practice (France)